Cubic Particulate Matter Sensors

Cubic Particulate Matter Sensors
Regular price $38.00 USD

POs or wholesale quantity discounts click here

Cubic's PM1.0, PM2.5, and PM10 combined Particulate Matter Sensors deliver fast, accurate and stable performance at an incredibly low price. They are designed to be used stand-alone or as the foundation of an OEM indoor air quality PM detector.

Features

  • Advanced laser scattering technology
  • Real-time output PM1.0, PM2.5, PM10 in μg/m³
  • Small, compact structure
  • All-metal shielding for strong anti-interference
  • High accuracy, high sensitivity and quick response
  • Industry-standard UART, I²C outputs
  • Four types of measuring modes: single/continuous/timing/dynamic
  • RoHS and Reach compliant

Models

  • PM2008M-M Sensor Module - UART, I2C, PWM, with inlet and outlet ports on the same side. Better accuracy at very low PM levels.
  • PM2012SE-A Sensor Module - UART, I2C. Opposite side ports.

PM2008M-M Specifications

  • Operating principle: Laser scattering
  • Measured particle range: 0.3μm~10μm
  • Measurement range: 0~5,000μg/m³
  • Resolution: 1μg/m³
  • Accuracy: (GRIMM, 25±2℃, 50 ±10%RH)
  • PM2.5/PM1.0:: 0~35μg/m³, ±5μg/m³, 35~500μg/m³, ±15% reading
  • PM10: 0~100μg/m³, ±25μg/m³, 101~500μg/m³, ±25% reading
  • Response time: 1 sec
  • Time to first reading: ≤ 8 seconds
  • Power supply: DC 5V±0.1V, ripple wave<50mV
  • Working current: ≤100mA
  • Standby current: ≤200μA
  • Dimensions: W48*H40*D12 mm
  • Digital output 1: UART: 3.3VDC, I2C 3.3-5VDC
  • Digital output 2: PWM (customized)
  • MTTF: 110,000 hours (continuous turn on)
  • Working condition: -10°C ~ 60°C, 0-95%RH (non-condensing)
  • Storage condition: -40°C ~ 80°C, 0-95%RH (non-condensing)
  • Weight: 6g

PM2012SE-A Specifications

  • Operating principle: Laser scattering
  • Measured particle range: 0.3μm~10μm
  • Measurement range: 0~5,000μg/m³
  • Resolution: 1μg/m³
  • Accuracy: (GRIMM, 25±2℃, 50 ±10%RH)
  • PM2.5/PM1.0:: 0~100μg/m³, ±10μg/m³, 101~500μg/m³, ±10% reading
  • PM10: 0~100μg/m³, ±25μg/m³, 101~500μg/m³, ±25% reading
  • Response time: 1 sec
  • Time to first reading: ≤ 8 seconds
  • Power supply: DC 5V±0.1V, ripple wave<50mV
  • Working current: ≤100mA
  • Standby current: ≤200μA
  • Dimensions: W38*H35*D12 mm
  • Digital output: UART/I2C: 3.3VDC/5VDC(Level)
  • MTTF: 110,000 hours (continuous turn on)
  • Working condition: -10°C ~ 60°C, 0-95%RH (non-condensing)
  • Storage condition: -40°C ~ 80°C, 0-95%RH (non-condensing)
  • Weight: 6g

Warranty

  • 90 days - See CO2Meter Terms and Conditions.

Cubic Software

Software supplied by the manufacturer lets you test and read single sensors using UART or multiple sensors in series using I2C.

Particle sensor software Particle Sensor Software (zip)

A cable to connect the sensors is not included. We suggest:

CU-PM2008M-M - LATTECH 5 PIN JST Cable

CU-PM2012SE-A - Harwin M50-3120545 On-board Connector

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Swift response and shipment. The product is easy to setup and use. It is just what I was looking for."

- Shima Tomohiro

Read More Reviews...